ACTIVATED CARBON SYSTEMS

Chloride and fluoride, which are liberated during the burning of chloride and fluoride compounds that are likely to be present in wastes, raw materials
and fossil fuels at high temperatures, react with aromatic organic substances to form permanent dangerous pollutants such as dioxin and furan.
Compounds are injected into the system where the flue gas temperature is around 140 -150 C in order to remove (absorb) pollutants such as dioxin
and furan.
The system ensures that the material coming with the bigbag is injected into the flue gas pipe in a controlled manner in the desired amount. The
material that comes with the bigbag is connected to the hanger of the bigbag unloading system by the operator. The bigbag is placed on the discharge
cone of the system with the help of a crane. The side cover of the discharge cone is opened and the mouth of the bigbag is untied. After the cover is
closed, the bigbag.
The material in it is discharged to the bunker of the system and from there to the intermediate tank. On the intermediate warehouse.The level
switches on it control the amount of material and send it to the control panel provides information. The material is transferred to the micro dosage
device with the flap located under the intermediate tank. In the micro dosing device, the material is dosed volumetrically and transferred to the
shipping bunker. The material transferred to the delivery bunker is transferred to the pipeline with the feeder. The air at the required pressure and flow
rate provided by the pump and motor group carries the material along the pipeline and injects it into the flue gas pipe. system control controlled
from the panel. amount of material; Coming from analog signals (0 – 10 VDC or 4 – 20 mA) to be given to the user interface or to us manually by the
operator will be injected into the flue gas pipe in line with the information.